Evaporative (FRP) Cooling towers

Evaporative (FRP) Cooling towers are of vertical induced draft counter flow desingn with uniform water
distribution and optimal heat transfer. Towers can be installed independent of wind direction.

Fills

The fill is of rigid Poly Vinyl Chloride (PVC) and is of honeycomb design with very large contact surface area. The fill splits the air and water into several streams, increasing the time of contact and also heat transfer betwee water and air. The fill is in modules and is packed in the tower casing without any cutting for curves. The air pressure drop through the fill is negligible. The fills are available with flute height of 6mm, 12mm, and 19mm with sheet thickness of 1mm and 1.2mm.

sprinkler

Sprinkler

Automatic rotary sprinkler system made of Nylon 66 material, with rotary head and sprinkler pipe distributes the hot water over the entire space of the filter, sprinkler pippes are non-clogging, require low pressure to operate and assures uniform water flow with minimal operating pump head. the FRP eliminators attached to sprinkler pipe are specifically designed for low pressure drop and minimises the drift loss of water.

Axial Fans

Specially designed energy efficient fans are of induced-draft axial type with adjustable pitch material chosen ar non corrosive of plastic, FRP or aluminium alloy. The high efficiency design ensures low running cost and the lowest possible noise level. Fan blade pitch is factory set and dynamically balanced.

axial fan
motors

Motors

The motors ar lotally enclosed (IP55), flange type, 415V, 3 ph, 50 Hz, induction weather proof with SS304 extended shaft and are specially designed for cooling tower application.

Cooling Towers

Technical Specification

Round Type FRP Cooling Tower

Base
Model
Motor
HP / RPM
Fan Dia,
mm
In / Out
Size (NB)
HAE 10RT0.5 / 1440
450 (PVC)
1½” / 1½”
HAE 15RT0.75 / 1440
700 (PVC)
2″ / 2″
HAE 20RT1 / 950
750 (NYLON)
2″ / 2½”
HAE 30RT1 / 950
750 (NYLON)
2½” / 3″
HAE 40RT1 / 950
850 (NYLON)
3″ / 3″
HAE 50RT2 / 950
900 (NYLON)
3″ / 3″
HAE 60RT3 / 950
1160 (AI)
3″ / 3″
HAE 80RT3 / 950
1160 (AI)
4″ / 4″
frp
square

Square Type FRP Cooling Tower

Base
Model
Motor
HP / RPM
Fan Dia,
mm
In / Out
Size (NB)
HAE 100ST5 / 950 1400 (AI) 5″ / 5″
HAE 150ST5 / 950 1400 (AI) 6″ / 6″
HAE 200ST7.5 / 7101800 (AI) 8″ / 8″
HAE 250ST10 / 7101800 (AI) 8″ / 8″
HAE 300ST12.5 / 6002200 (AI) 8″ / 8″
HAE 400ST15 / 360
2400 (AI) 10″ / 10″
HAE 500ST20 / 3603000 (AI) 10″ / 10″

INPUT PARAMETERS REQUIRED FOR SLECTION

  • 1
    Hot Water Temperature
  • 2
    Cold Water Temperature
  • 3
    Wet Bulb Temperature
  • 4
    Water Flow

Check out our work

Take a peek inside our Wonderworld

Application

Chemical Industry,  Food & Beverage Industry,  GIass Industy, Pharmaceutical Industry, Plastic Industry, Distilleries Breweries / Healthcare / Hospitals, Oil cooler, Metal Spraying, Oncology Machine, Printing Process, PET-Stretch Blow Moulding process chilling, Textile Processing, Welding Machine and many more.

Catalogue

Download catalogue for your reference

Our prestige clients